Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
267
6.3.4.2
no spanning-tree
Description
With this command, you reset the various properties of the spanning tree function to the
default value:
The default values are as follows:
Parameter
Default value
cost
if dynamic calculation of the path costs is not enabled:
• 200000 for physical interfaces
• 199999 for port channels
disable
The spanning tree function is enabled on the interface
link-type
• point-to-point
The connection is configured as full-duplex
•
shared
in all other cases
portfast
disabled
port-priority
128
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no spanning-tree {cost|disable|link-type|portfast|port-priority}
The parameters have the following meaning:
Parameter
Description
cost
Keyword for the costs of the port for calculating the lowest-cost path.
disable
Enables the interface for spanning tree.
link-type
Connection status of the following network segment
portfast
Disables the PortFast function.
port-priority
Keyword for the priority of the interface

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals