Page #107 background image
Functions specific to SCALANCE
4.4 iPCF-MC
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
107
4.4.2.4
wlan ipcf-mc mgmt-scan-period (client)
Note
The command is only available with the following device:
•
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
Description
With this command, you the time for the background scan interval as a multiple of the update
time.
Requirement
The SCALANCE W700 device is in client mode
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call up the command with the following parameters:
wlan ipcf-mc mgmt-scan-period <num-of-cycles (1-10)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
num-of-cycles
Duration
1 ... 10
Result
The time is set.
Further notes
You display the setting with the show wlan ipcf-mc command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals