Network structures
6.2 VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
222 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.2.1.7
show vlan learning params
Description
This command shows the parameters for the automatic learning of addresses for selected or
all VLANs (active and inactive VLANs).
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
show vlan learning params[vlan<vlan-range>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
vlan
Keyword for a VLAN or VLAN range
-
vlan-range
Number of the addressed VLAN or
VLAN range
1 ... 4094
If you do not select any parameter from the parameter list, the entries of all available
interfaces are displayed.
Result
The settings for the automatic learning of addresses are displayed.
6.2.1.8
show vlan port config
Description
This command shows the VLAN-specific information for ports.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals