Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
254 Configuration Manual, 10/2015, C79000-G8976-C351-05
Result
The automatic discovery of a bridge on the interface is disabled.
Further notes
You enable the automatic detection with the spanning-tree l2t-auto-edge command.
You can display the status of this function with the
show spanning-tree l2t-edgecommand.
6.3.3.7
spanning-tree l2t-edge
Description
With this command, you specify that an end device can be located at a layer 2 tunnel port.
Otherwise a reconfiguration of the network will be triggered whenever a link to this port is
modified. The L2T clients should be interconnected.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
spanning-tree l2t-edge
Result
The setting is enabled.
Further notes
You disable the setting with the no spanning-tree l2t-edge command.
You can display the status of this function with the
show spanning-tree l2t-edgecommand.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals