Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
188 Configuration Manual, 10/2015, C79000-G8976-C351-05
Requirement
DFS is enabled.
The access point does not select the channel automatically.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
wlan dfs prefer-configured-channel
Result
The function is enabled.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
You disable the function with the
no wlan dfs prefer-configured-channel command (default
setting).
6.1.5.36
no wlan dfs prefer-configured-channel
Description
With this command you disable the access point changing back to the configured channel
automatically after the channel is released again following a blockage.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
no wlan dfs prefer-configured-channel
Result
The function is disabled.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals