Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
337
Syntax
Call up the command with the following parameters:
no snmp community index <CommunityIndex>
The parameter has the following meaning:
Parameter
Description
Range of values / note
CommunityIndex
Name of the community
max. 32 characters
Result
The details of an SNMP community are deleted.
Further notes
You configure the details of an SNMP community with the snmp community index command.
You show the details of an SNMP community with the
show snmp community command.
You show the status information of the SNMP communication with the
show snmp command.
7.4.2.8
snmp filterprofile
Description
With this command, you configure a filter that describes the access rights to the MIB tree.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals