Page #434 background image
Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
434 Configuration Manual, 10/2015, C79000-G8976-C351-05
11.1.1.1
show authlog
Description
With this command, you show the information about successful or failed authentication
attempts.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show authlog
or
Call up the command with the following parameters:
show authlog [{ info | warning | critical }]
The parameters have the following meaning:
Parameter
Description
info
All log entries of the category "Information" are displayed.
warning
All log entries of the category "Warning" are displayed.
critical
All log entries of the category "Critical" are displayed.
Result
The content of the logbook is displayed.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals