SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
64 Configuration Manual, 10/2015, C79000-G8976-C351-05
The parameters have the following meaning:
Parameters
Description
transmit
the sending of LLDP packets is enabled
receive
the receipt of LLDP packets is disabled
Note
Disabling both options
When you call this command, you can only select one option.
If you want to disable both options, call up the command again.
Result
The setting is configured.
Further notes
You enable the sending or receipt of LLDP packets with the lldp command.
You display the status of LLDP with the
show lldp status command.
3.1.10.7
mtu
Description
With this command, you configure the size of the Maximum Transmission Unit (MTU) for an
interface.
Requirement
The Interface must be shut down.
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
mtu <frame-size(64-1514)>

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals