Description
2.5 Interface identifiers and addresses
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
25
2.5
Interface identifiers and addresses
2.5.1
Naming interfaces
Addressing interfaces
The device has several types of interface that are addressed in different ways:
Addressing physical interfaces
This notation also applies to other commands that address an Interface.
Enter the command "
interface".
Specify the interface type
<interface-type>.
After a space, enter the interface identifier,
<interface-id>.
The interface identifier is made up of the module number and the port number separated
by a slash. The interfaces permanently installed in the device are identified with module
0.
Examples:
Fast Ethernet:
interface fa 0/1
WLAN1:
interface wlan 0/1
Addressing logical interfaces
This notation also applies to other commands that address a logical interface.
VAP / WDS
Enter the command "
interface".
Specify the interface type
<interface-type>.
After a space, enter the interface identifier,
<interface-id>.
The interface identifier is made up of the module number and the port number
separated by a slash. The interfaces permanently installed in the device are identified
with module 0.
Example:
VAP 1.1:
interface vap1 0/1
VLAN
Enter the command "
interface".
Enter the keyword for the VLAN interface.
After a space, enter the number of the VLAN interface you assigned when you created
it.
Example:
VLAN 2:
interface vlan 2

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals