Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
206 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.1.5.56
wlan rts-cts threshold
Description
With this command, you specify the packet size starting at which RTS/CTS (Request To
Send/Clear To Send) will be used.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan rts-cts threshold < bytes(1-2346)>
The parameter has the following meaning:
Parameters
Description
Range of values / note
bytes
Size specified in bytes 1...2346
Default: 2346
Result
The packet size is specified.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
6.1.6
Commands in the VAP Interface Configuration mode
This section describes commands that you can call up in the VAP Interface Configuration
mode. Depending on the Interface selected, various command sets are available.
In the Global Configuration mode, enter the
interface vapX 0/Y command to change to this
mode.
If you exit the VAP Interface Configuration mode with the
exit command, you return to
the Global Configuration mode.
If you exit the VAP Interface Configuration mode with the
end command, you return to the
Privileged EXEC mode.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals