Security and authentication
10.3 Management Access Control List
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
428 Configuration Manual, 10/2015, C79000-G8976-C351-05
10.2.5.11
no vap communication with ethernet (access point)
Description
With this command, you specify that the client cannot communicate via the Ethernet
interface.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with ethernet
Result
The communication option is disabled.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You enable the function with the
vap communication with ethernet command.
See also
vap communication with ethernet (access point) (Page 427)
10.3
Management Access Control List
This section describes the commands relevant for working with the management access
control list.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals