Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
164 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.1.5.10
no wlan amsdu
Description
With this command, you disable the sending of A-MSDU data packets. If the function is
disabled, only A-MSDU data packets can be received.
Requirement
The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
no wlan amsdu
Result
The sending of A-MSDU data packets is disabled.
Further notes
You display the setting with the show wlan advanced-11n <wlan 0/X> command.
You enable the function with the
wlan ampsu command (default setting).