Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
336 Configuration Manual, 10/2015, C79000-G8976-C351-05
The parameters have the following meaning:
Parameter
Description
Range of values / note
CommunityIndex
Index of the community
max. 32 characters
name
Keyword for the name of the communi-
ty
-
CommunityName
Name of the community
max. 32 characters
security
Keyword for the security name -
SecurityName
Security name
max. 32 characters
context
Keyword for the context name
-
Name
Context name
max. 32 characters
Storage type specifies whether the settings remain
following a restart
volatile (volatile):
The settings are lost after a
restart
nonvolatile (non-volatile):
The settings are retained after
a restart
If optional parameters are not specified when configuring a community, the default values
apply.
Result
The settings are configured.
Further notes
You delete the details of an SNMP community with the no snmp community index command.
You show the details of an SNMP community with the
show snmp community command.
You show the status information of the SNMP communication with the
show snmp command.
7.4.2.7
no snmp community index
Description
With this command, you delete the details of an SNMP community.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#