Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
181
Syntax
Call the command without parameter assignment:
no wlan data rates-11n selected only
Result
The function is disabled. The data transmission speed is adapted automatically.
Further notes
You display the setting with the show wlan data rates command.
You enable the function with the
wlan data rates-11abg selected only command.
You configure the transmission standard with the
wlan mode command.
6.1.5.29
wlan data rate-11abg (access point)
Description
With this command, you assign data transmission speeds to the required WLAN interface.
The access point will then use only the selected data transmission speeds for
communication with the clients.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11a/b/g/n is set.
The "Use selected data rates only" function is enabled.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals