Network protocols
7.5 SMTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
358 Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call the command without parameters:
no sender mail-address
Result
The e-mail name of the sender is reset.
Further notes
You configure the e-mail name of the sender with the sender mail-address.
You display the setting with the
show events sender email command.
7.5.2.5
smtp-port
Description
With this command, you configure an SMTP port.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-port <smtp-port(1-65535)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
smtp-port
Value for the SMTP port 1 ... 65535
Default: 25
Result
An SMTP port is configured.
Further notes
You can reset the setting to the default with the no smtp-port command.
You display the setting with the
show smtp-port command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals