Network structures
6.2 VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
235
6.2.3.9
no switchport pvid
Description
With this command, you reset the setting for the port VLAN identifier (PVID) for an interface
to the default value.
The default value is 1.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport pvid
Result
The setting is reset to the default value.
Further notes
You configure the setting with the switchport pvid command.
You configure the VLAN ID with the
switchport access vlan command.
You can display the status of this function and other information with the
show vlan port
config
command.
6.2.4
Commands in the VLAN configuration mode
This section describes commands that you can call up in the VLAN Configuration mode.
In the Global Configuration mode, enter the
vlan $$$ command to change to this mode.
When doing this, you need to replace the
$$$ placeholders with the relevant VLAN ID.
Commands relating to other topics that can be called in the VLAN Configuration mode can
be found in the relevant sections.
If you exit the VLAN Configuration mode with the
exit command, you return to the Global
Configuration mode.
If you exit the VLAN Configuration mode with the
end command, you return to the
Privileged EXEC mode.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals