Layer 3 functions
9.1 NAT
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
380 Configuration Manual, 10/2015, C79000-G8976-C351-05
9.1.3.7
no nat timeout (Client)
Note
This command is only available in the client mode.
Description
With this command, you delete the time period for the TCP / UDP connection.
Requirement
You are now in the NAT Configuration mode.
The command prompt is as follows:
cli(config-nat)#
Syntax
Call up the command with the following parameters:
no nat {tcp|udp} timeout
The parameters have the following meaning:
Parameters
Description
Range of values / note
tcp
TCP connection
-
udp
UDP connection
-
Result
The time period for the TCP / UDP connection was set to the default setting.
Further notes
You show the NAT configuration and the translation list with the show nat command.
You configure the time with the
nat timeout command.
See also
show nat (Client) (Page 371)

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals