Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
332 Configuration Manual, 10/2015, C79000-G8976-C351-05
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no snmpagent
Result
The SNMP agent function is disabled.
Further notes
You enable the SNMP agent function with the snmpagent command.
7.4.2.3
snmp agent version
Description
With this command, you configure whether all SNMP queries or only SNMPv3 queries are
processed.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp agent version{v3only|all}
The parameters have the following meaning:
Parameter
Description
Range of values / note
v3only
only SNMPv3 queries are processed
-
all
all SNMP queries are processed
Default: all
Result
The setting is configured.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals