Configuration
3.4 Configuration Save & Restore
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
84 Configuration Manual, 10/2015, C79000-G8976-C351-05
If you call up the command without parameters, only the active operational settings of all
modules and all interfaces that do not match the preset values are displayed.
Result
The selected configuration settings of the device are displayed.
3.4.2
write startup-config
Description
With this command, you save the changes to the configuration in the configuration file.
The use of this command is required in the Trial mode. It can also be used in "auto save
mode".
Requirement
The Trial mode is activated.
You are in the Privileged EXEC mode.
The command prompt is:
*cli(...)#
Syntax
Call the command without parameter assignment:
write startup-config
Result
The changes are saved in the configuration file.
Use the
restart command without parameters to restart the system with this configuration.
Further notes
You enable the auto save function or disable the Trial mode with the auto-save command.
You disable the auto save function or enable the Trial mode with the
no auto-save
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals