EasyManuals Logo

Siemens SIMATIC NET Configuration Manual

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #259 background imageLoading...
Page #259 background image
Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
259
Result
The setting for the maximum number of hops is configured.
Further notes
You can reset the setting for the maximum number of nodes to the default with the no
spanning-tree mst max-hops
command.
You display this setting and other information with the
show spanning tree mst
configuration
command.
6.3.3.13
no spanning-tree mst max-hops
Description
With this command, you reset the maximum number of hops that a path in an MST can run
through to the default value.
The default value is 20.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree mst max-hops
Result
The setting for the maximum number of nodes is reset to the default value.
Further notes
You can configure the setting for the maximum number of nodes with the spanning-tree mst
max-hops
command.
You display this setting and other information with the
show spanning tree mst
configuration
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals