EasyManuals Logo

Siemens SIMATIC NET Configuration Manual

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Functions specific to SCALANCE
4.4 iPCF-MC
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
106 Configuration Manual, 10/2015, C79000-G8976-C351-05
4.4.2.3
wlan ipcf-mc cycle-time (access point)
Note
The com
mand is only available with the following device:
•
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
Description
With this command, you configure the cycle time for iPCF-MC.
Requirement
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call up the command with the following parameters:
wlan ipcf-mc cycle-time <ms (32-512)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
ms
Cycle time in millisec-
onds (ms)
32 ... 512
Result
The cycle time is configured.
Further notes
You display the setting with the show wlan ipcf-mc command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals