Network protocols
7.2 DHCP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
301
Result
The IP address is assigned again.
This address can be a different address from the previously assigned address.
Further notes
You can display the statistical information of the DHCP client with the show ip dhcp client
stats
command.
You show the statistical information and the configuration of the IP interface with the
show ip
interface
command.
7.2.3
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
7.2.3.1
ip dhcp config-file-request
Description
If the DHCP config file request option is set, the device requests the TFTP address and the
name of a configuration file from the DHCP server. If the device is restarted following the
completed download, the configuration settings are read from this file.
With this command, you enable the DHCP config file request option.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
ip dhcp config-file-request

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals