EasyManua.ls Logo

Siemens SIMATIC NET

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
147
6.1.1.17
show wlan vap (access point)
Description
This command shows the configuration of the VAP interface.
Note
This command is available only in access
point mode.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
show wlan vap <vapX 0/Y>
The parameter has the following meaning:
Parameter
Description
Range of values / note
vapX 0/Y
VAP interface
Enter a valid interface.
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The following settings of the VAP are displayed:
Admin status
SSID
Broadcast SSID
WDS only
WDS ID

Table of Contents

Other manuals for Siemens SIMATIC NET

Related product manuals