Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
132 Configuration Manual, 10/2015, C79000-G8976-C351-05
The parameter has the following meaning:
Parameter
Description
Range of values / note
wlan 0/X
WLAN interface
Enter a valid interface.
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The following settings are displayed:
RTS/CTS threshold
Fragmentation length threshold
HW retries
In Access Point mode, the following additional settings are displayed:
Beacon interval
DTIM
Force roaming on link down
Overlap AP aging interval
6.1.1.2
show wlan allowed channels
Description
This command displays the available wireless channels. If you have selected channels
explicitly for wireless communication, this information is also displayed.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
show wlan allowed channels <wlan 0/X>
The parameter has the following meaning:
Parameter
Description
Range of values / note
wlan 0/X
WLAN interface Enter a valid interface.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals