Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
258 Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call up the command with the following parameters:
spanning-tree mst{instance-id<instance-id(1-64)>}root
The parameters have the following meaning:
Parameter
Description
Range of values / note
instance-id
Keyword for the instance
-
instance-id
Number of the instance 1 ... 64
Result
The "root bridge" function is disabled.
Further notes
You enable the root bridge function with the spanning-tree mst instance-id root command.
You display this setting and other information with the commands that start with
show
spanning tree ...
.
6.3.3.12
spanning-tree mst max-hops
Description
With this command, you configure the maximum number of nodes (hops) that a path can run
through in an MST.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
spanning-tree mst max-hops <value(6-40)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
value
Maximum number of hops that a path
can run through in an MST
6 ... 40
Default: 20

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals