Network protocols
7.1 IPv4 protocol
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
298 Configuration Manual, 10/2015, C79000-G8976-C351-05
7.1.3.4
dcp forwarding
Description
With this command, you configure the forwarding behavior of the interface for DCP frames.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
dcp forwarding {block|forward}
The parameters have the following meaning:
Parameter
Description
block
DCP frames are discarded
forward
DCP frames are forwarded
Default:
forward
Result
The forwarding behavior of the interface for DCP frames is configured.