Network protocols
7.3 DHCP server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
312 Configuration Manual, 10/2015, C79000-G8976-C351-05
7.3.3
Commands in the DHCPPOOL configuration mode
This section describes commands that you can call up in the DHCPPOOL Configuration
mode.
In the Global Configuration mode, enter the
ip dhcp-server pool command to change to this
mode.
If you exit the DHCPPOOL Configuration mode with the
exit command, you return to the
Global Configuration mode.
If you exit the DHCPPOOL Configuration mode with the
end command, you return to the
Privileged EXEC mode.
7.3.3.1
lease-time
Note
The command is only available with the following device:
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-
0AA0
and 6GK5761-1FC00-0AB0 (US version))
Description
With this command, you specify how long the assigned IPv4 address remains valid. Once
this period has elapsed, the device must either request a new IPv4 address or extend the
lease time of the existing IPv4 address.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call up the command with the following parameters:
lease-time <seconds (60-31536000)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
seconds
Time until renewal of the assigned
IPv4 address in seconds
60 ... 31536000

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals