6.1.5.55
wlan roaming threshold (client)
Description
With this command, you specify the threshold after which the client roams to the new access
point.
Note
This command is only available in the client mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan roaming threshold { low | medium | high }
The parameters have the following meaning:
Parameter
Description
low
Even if the difference in field strength is low, change to the AP with the stronger
signal.
medium
If the difference in field strength is medium, change to the AP with the stronger
signal.
Default: medium
high
If the difference in field strength is high, change to the AP with the stronger sig-
nal.
Result
The threshold is specified.
Further notes
You display the setting with the show wlan client <wlan 0/X> command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals