Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
205
6.1.5.55
wlan roaming threshold (client)
Description
With this command, you specify the threshold after which the client roams to the new access
point.
Note
This command is only available in the client mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan roaming threshold { low | medium | high }
The parameters have the following meaning:
Parameter
Description
low
Even if the difference in field strength is low, change to the AP with the stronger
signal.
medium
If the difference in field strength is medium, change to the AP with the stronger
signal.
Default: medium
high
If the difference in field strength is high, change to the AP with the stronger sig-
nal.
Result
The threshold is specified.
Further notes
You display the setting with the show wlan client <wlan 0/X> command.