Configuration
3.1 System
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
44 Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call the command without parameters:
show versions
Result
The following settings are displayed:
Basic device
Name
Revision
Order ID
Firmware
Bootloader
Description
Version
Date
3.1.2
clear counters
Description
With this command, you reset the counters of an interface.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
clear counters [<interface-type><interface-id>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
interface-type
Type or speed of the interface
Specify a valid interface.
interface-id
Module no. and port no. of the interface

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals