EasyManuals Logo

Siemens SIMATIC NET Configuration Manual

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #308 background imageLoading...
Page #308 background image
Network protocols
7.3 DHCP server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
308 Configuration Manual, 10/2015, C79000-G8976-C351-05
7.3.2.3
ip dhcp-server icmp-probe
Note
The command is only available with the following device:
•
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
•
SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-
0AA0
and 6GK5761-1FC00-0AB0 (US version))
Description
With this command, you enable the "Probe address with ICMP Echo before offer" function.
The DHCP server checks whether or not the IPv4 address has already been assigned. If no
reply is received, the DHCP server can assign the IPv4 address.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
ip dhcp-server icmp-probe
Result
The function is enabled.
Further notes
You disable the function with the no ip dhcp-server icmp-probe command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals