Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
437
Syntax
Call the command without parameters:
show events faults status
Result
A table with the status messages of the error monitoring functions is displayed.
11.1.1.6
show fault counter
Description
This command shows the number of fault transitions of the power supply and network
connections.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show events fault counter
Result
The number of indicated faults is displayed.
11.1.1.7
show logbook
Description
With this command, you display the content of the logbook. The log entries are categorized
differently.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#