Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
204 Configuration Manual, 10/2015, C79000-G8976-C351-05
Result
The indoor mode is enabled or the outdoor mode is disabled.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.
You enable the outdoor mode with the
wlan outdoor command.
See also
wlan outdoor (Page 203)
6.1.5.54
wlan overlap-ap aging (access point)
Description
With this command, you configure the aging time for the list of overlapping access points. If
an access point is inactive for longer than the set time, it is removed from the list.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan overlap-ap aging <min(1-7200)>
The parameter has the following meaning:
Parameters
Description
Range of values / note
min
Time in minutes (min) 1...7200
Default: 120
Result
The aging time is specified.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals