Page #256 background image
Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
256 Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call the command without parameters:
spanning-tree mst configuration
Result
You are now in the MSTP configuration mode.
The command prompt is as follows:
cli(config-mst)#
Further notes
You exit the MSTP configuration mode with the end or exit command.
6.3.3.10
spanning-tree mst instance-id root
Description
With this command you specify whether the device is a root bridge (primary) or a substitute
root bridge (secondary).
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#