Network protocols
7.1 IPv4 protocol
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
292 Configuration Manual, 10/2015, C79000-G8976-C351-05
Result
The DNS client of the device is enabled and when necessary sends queries to the DNS
server.
7.1.2.10
no ip domain lookup
Description
This command disables the DNS client of the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no ip domain lookup
Result
The DNS client of the device is disabled.
7.1.2.11
ip name-server
Description
This command specifies an IP address of a DNS server. If there is more than one server,
you can specify the order in which the servers are queried. To allow this, the optional
parameter
index is available. The server with the lowest index is queried first.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals