Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
333
7.4.2.4
snmp access
Description
With this command, you configure the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName>{v1|v2c|v3{auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
GroupName
Name of the group to which access is
configured
max. 32 characters
- Selects the version of the protocol
used
•
v1
•
v2c
•
v3
- Selects the authentication method:
•
auth
enables MD5 or SHA as au-
thentication method
• noauth
no authentication
•
priv
enables authentication and
encryption
read
the data can be read
Keyword
•
ReadView
•
none
write
the data can be read and written
Keyword
•
WriteView
•
none

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals