EasyManuals Logo

Siemens SIMATIC NET Configuration Manual

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #159 background imageLoading...
Page #159 background image
Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
159
6.1.5.4
wlan alternative channel (access point)
Description
If you have activated the DFS function, you specify the alternative channel with this
command. If the access point on the current channel discovers a disruption, it switches to
the alternative channel.
Note
This command is available only in access point mode.
Requirement
The DFS function is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan alternative channel { show-channels | <number (0=auto)> }
The parameters have the following meaning:
Parameters
Description
Range of values / note
show-channels
Lists all available channels.
--
number
Number of the alternative channel
If you want the access point to
search for a free channel itself, use
"0".
Default value: 0 (AUTO)
Result
The alternative channel is set.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.
You enable the DFS function with the
wlan dfs command.
See also
wlan dfs (Page 186)

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals