Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
162 Configuration Manual, 10/2015, C79000-G8976-C351-05
Requirement
The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ampdu bytes-limit <bytes(1024-65535)>
The parameter has the following meaning:
Parameters
Description
Range of values / note
bytes
Size of the AMPDU data packet in bytes 1024 to 65535 bytes
Default: 50000 bytes
Result
The size for the AMPDU data packets is specified.
Further notes
You display the setting with the show wlan advanced-11n <wlan 0/X> command.
6.1.5.8
wlan ampdu frames-limit
Description
With this command, you specify the number of individual data packets (frames) grouped
together in one AMPDU data packet.
Requirement
The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ampdu frames-limit <frames(2-64)>

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals