Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
334 Configuration Manual, 10/2015, C79000-G8976-C351-05
Parameter
Description
Range of values / note
notify
Changes can be set as a tag
Keyword
NotifyView
none
Storage type specifies whether the settings remain
following a restart
volatile (volatile):
The settings are lost after a
restart
nonvolatile (non-volatile):
The settings are retained after
a restart
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
Further notes
You delete the access to an SNMP group with the no snmp access command.
You display the configured SNMP groups with the
show snmp group command.
You display the access configurations for SNMP groups with the
show snmp group access
command.
You display the configured SNMP tree views with the
show snmp viewtree command.
7.4.2.5
no snmp access
Description
With this command, you delete the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName>{v1|v2c|v3{auth|noauth|priv}}