Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
255
6.3.3.8
no spanning-tree l2t-edge
Description
With this command, you disable the setting that an end device may be located at a layer 2
tunnel port.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree l2t-edge
Result
The setting is disabled.
Further notes
The automatic discovery of a bridge on the interface is disabled with the spanning-tree l2t-
edge
command.
You can display the status of this function with the
show spanning-tree l2t-edgecommand.
6.3.3.9
spanning-tree mst configuration
Description
With this command, you change to the MSTP configuration mode.
Requirement
MSTP is enabled
Compatibility mode: MSTP
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals