Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
194 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.1.5.43
wlan fragmentation threshold
Description
With this command, you specify the maximum packet size transferred on the wireless link.
Large packets are divided up into small packets prior to transmission and then reassembled
into the original size after they have been received.
Requirement
The transmission standard 802.11g or 802.11a is set.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan fragmentation threshold <bytes(256-2346)>
The parameter has the following meaning:
Parameters
Description
Range of values / note
bytes
Packet size in bytes 256...2346
Default: 2346
Result
The packet size is specified.
Further notes
You configure the transmission standard with the wlan mode command.
You display the setting with the
show wlan advanced <wlan 0/X> command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals