Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
341
Syntax
Call up the command with the following parameters:
no snmp group <GroupName> user <UserName>security-model{v1|v2c|v3}
The parameters have the following meaning:
Parameter
Description
Range of values / note
GroupName
Name of the group
max. 32 characters
user
Keyword for the user name -
UserName
Name of the user
max. 32 characters
security-model
Specifies which security settings are
used for sending
•
v1
•
v2c
•
v3
Result
The details of the group are deleted.
Further notes
You change the details of an SNMP group with the snmp group command.
You display the created SNMP groups with the
show snmp group command.
You display the created SNMP user with the
show snmp user command.
7.4.2.12
snmp notify
Description
With this command, you configure the details of the SNMP notifications.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals