Security and authentication
10.2 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
417
10.2.5
Commands in the VAP Interface configuration mode
This section describes commands that you can call up in the VAP Interface Configuration
mode. Depending on the Interface selected, various command sets are available.
In the Global Configuration mode, enter the
interface vapX 0/Y command to change to this
mode.
If you exit the VAP Interface Configuration mode with the
exit command, you return to
the Global Configuration mode.
If you exit the VAP Interface Configuration mode with the
end command, you return to the
Privileged EXEC mode.
10.2.5.1
vap security authentication (access point)
Description
With this command, you specify the type of authentication.
Note
This command is available only in access point mode.
Note
iPCF or iPCF-MC mode enabled
If iPCF or iPCF
-MC mode is enabled, only "Open System" with the encryption method AES
is supported in the security settings.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals