Functions specific to SCALANCE
4.1 WBM
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
93
Syntax
Call up the command with the following parameters:
web-session-timeout[seconds(60-3600)]
The parameter has the following meaning:
Parameter
Description
Range of values / note
seconds
Time in seconds until automatic logout
after the last entry
60 … 3600
Default: 900
Result
The time is configured and automatic logout is enabled.
Further notes
You disable automatic logoff with the no web-session-timeout command.
You display the current timeout setting with the
show web-session-timeout command.
4.1.2.2
no web-session-timeout
Description
With this command, you disable the automatic logoff.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no web-session-timeout
Result
Automatic logoff is disabled.
Further notes
You enable automatic logoff with the web-session-timeout command.
You display the current timeout setting with the
show web-session-timeout command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals