Configuration
3.1 System
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
52 Configuration Manual, 10/2015, C79000-G8976-C351-05
The parameter has the following meaning:
Parameter
Description
Range of values / note
longitude
Input box for the longitude coordinate max. 32 characters
To use spaces in the entry, enter
the longitude coordinate in
quotes: coordinates longitude
"123 456"
Result
The longitude coordinate is created.
3.1.9.4
ethernetip
Description
With this command, you set whether EtherNet/IP will be enabled or disabled after the next
device restart.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ethernetip {off|on}
The parameters have the following meaning:
Parameter
Description
Range of values / note
off
EtherNet/IP will be disa-
bled after the next re-
start.
-
on
EtherNet/IP will be ena-
bled after the next re-
start.
• When EtherNet/IP is turned on, PNIO is turned off. The
switchover from EtherNet/IP and PNIO has no effect on
DCP.
• If a PROFINET connection is established; in other words
the PNIO AR status is "Online", you cannot enable
EtherNet/IP.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals