Network protocols
7.3 DHCP server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
320 Configuration Manual, 10/2015, C79000-G8976-C351-05
7.3.3.8
no pool-enable
Note
The command is only available with the following device:
•
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
•
SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-
0AA0
and 6GK5761-1FC00-0AB0 (US version))
Description
With this command you specify that this IPv4 address band will not be used.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call the command without parameter assignment:
no pool-enable
Result
The setting is disabled.
Further notes
You display the setting with the show ip dhcp-server pools command.
You enable the setting with the
pool-enable command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals