Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
170 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.1.5.17
wlan any ssid (Client)
Description
With this command, you enable the "Any SSID" function. This setting is activated as default.
In client mode, the SCALANCE W700 attempts to connect to the access point with the best
transmission quality and that has suitable security settings. The clients can only connect to
the access point on which the "Broadcast SSID" option is enabled.
Note
This command is only available in the client mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
wlan any ssid
Result
The function is enabled.
Further notes
You display the setting with the show wlan client <wlan 0/X> command.
You disable the function with the
no wlan any ssid command.
See also
no wlan any ssid (client) (Page 171)
vap broadcast ssid (access point) (Page 209)

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals