Network structures
6.2 VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
232 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.2.3.5
no switchport ingress-filter
Description
With this command, you disable the ingress filter.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport ingress-filter
Result
The ingress filter is deactivated.
Further notes
You enable the filter with the switchport ingress-filter command.
You can display the status of the ingress filter and other settings with the
show vlan port
config
command.
6.2.3.6
switchport priority default
Description
With this command, you configure the priority default for the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals