Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
171
6.1.5.18
no wlan any ssid (client)
Description
With this command, you disable the "Any ssid" function. The client attempts to connect to the
access point from the SSID list that provides the best transmission quality and on which the
"Broadcast SSID" option is disabled.
Note
This command is only available in the client mode.
Requirement
An active SSID is available.
You are in the Interface configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
no wlan any ssid
Result
The function is disabled.
Further notes
You display the setting with the show wlan client <wlan 0/X> command.
You enable the function with the
wlan any ssid command (default setting).
See also
wlan any ssid (Client) (Page 170)

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals