Network structures
6.2 VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
231
Requirement
You are in the interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no switchport access vlan
Result
The setting is reset to the default value.
Further notes
You configure the setting with the switchport access vlan command.
You can display the status of this function and other information with the
show vlan port
config
command.
6.2.3.4
switchport ingress-filter
Description
With incoming packets, the ingress filter checks whether the port on which the packet was
received belongs to the sending VLAN. If this is not the case, the packet is not processed.
With this command, you enable the ingress filter.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
switchport ingress-filter
Result
The ingress filter is activated.
Further notes
You disable the filter with the no switchport ingress-filter command.
You can display the status of the ingress filter and other settings with the
show vlan port
config
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals