Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
348 Configuration Manual, 10/2015, C79000-G8976-C351-05
7.4.2.18
snmp v1-v2 readonly
Description
With this command, you block write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is blocked.
Further notes
You release write access for SNMPv1 and SNMPv2 PDUs with the no snmp v1-v2 readonly
command.
7.4.2.19
no snmp v1-v2 readonly
Description
With this command, you enable write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no snmp v1-v2 readonly

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals